The S4000 range of high precision Cooled Mirror Dew-point Hygrometers offer unmatched accuracy and reliability in dew-point measurement and calibration. The powerful three-stage Peltier thermoelectric heat pump, coupled with integrated auxiliary refrigerant cooling, gives an effective measurement range down to -85°Cdp for the S4000 RS and to -100°Cdp for the S4000 TRS.
Caractéristiques produits
- 0.1°Cdp accuracy
- Measurement range: -100 to +20°Cdp
- Precision 4-wire Pt100 1/10 DIN class B Sensor
- Dual optics detection system
- Swagelok® or VCR® couplings
- Dual multi-function LED display with unit indicator
|
 |
Spécifications techniques |
| Performance |
| Measurement Technology |
Cooled Mirror |
| Measurement Range |
RS: -85 to +20°Cdp TRS: -100 to +20°Cdp |
| Measurement Accuracy |
±0.1°Cdp
±0.1°C temperature
|
| Measurement Units |
°Cdp, °Fdp; °C, °F temperature; % RH, ppmV, ppmW, g/m³, g/kg,
ppmW for SF6
|
| Response Speed |
0.5°C/sec plus settling time (dew-point dependant) |
| Sensitivity |
0.01°C |
| Repeatability |
Better than 0.1°C |
| Resolution |
0.01 (0.1 for % RH) |
| Dew-Point Sensor
|
| Mirror |
Gold plated copper |
| Temperature Measurement |
4 wire 1/10 DIN class B Pt100 |
| Sample Flow Rate |
0.1 to 0.7 l/min (recommended) |
| Integrated Flowmeter |
0 to 1 l/min |
| Sensor Pressure |
Atmospheric |
| Auxiliary Cooling |
Internal refrigeration |
| Remote PRT |
| Temperature Measurement |
4 wire 1/10 DIN class B Pt100
|
| Monitor |
| Resolution |
0.01°C |
| Dual Optics Detection |
Wide band red LED with dual photo
sensors, all systems insulated |
| Outputs |
Analogue: 2 channels: 10mV/°Cdp, 4-20 mA
Digital: RS232
Logic: data hold ABC logic status, optics alarm |
| Auxiliary Input |
Pressure transducer: 4-20 mA input for
automatic compensation 0 - 0.34 MPa (optional) |
| Operating Temperature |
0 to +40°C |
| Dimensions |
RS: 482 x 510 x 402mm (w x d x h) - Sub Rack
TRS: 560 x 600 x 860mm (w x d x h) - Mini Rack
|
| Weight |
RS: 31.5kg TRS: 85.0kg
|
| Power Supply |
Monitor: 90 to 265 V AC; 50-60
Hz Sensor: 100 to 115 or 220 to 240 V AC; 50-60 Hz |
|
Applications |
 |
Produits associés |
 |
S8000
Integrale The new S8000 Integrale continues Michells tradition of
excellence in the design of high... |
|
 |
S4000 Remote The
S4000 Remote is a precision laboratory dew-point hygrometer with the ultimate
accuracy... |
|
 |
Optidew
Vision The Optidew Vision precision dew-point meter is based on the
proven, fundamental optical dew... |
|
 |
Optidew The Optidew high
performance optical dew-point transmitter is based on the proven,
fundamental... |
|
 |
HG-10 The HG-10 is a completely
automatic temperature and humidity calibration system, which can be... |
|
 |
HG-1 The HG-1 is a high
precision, portable humidity calibrator. Using Michells Optidew Cooled...
|
|
 |
OptiCal OptiCal offers
the opportunity to provide local calibration of RH sensors that is directly...
|
|
 |
DCS The DCS is a dew-point
calibration system designed for the calibration, verification and... |
|
|
|
 |
Pressure Swing Dryers The PSD-Series is
designed specifically for calibration applications. It utilises two
desiccant... |
|
|