| GENERAL |
| Sensor Type |
Michell Advanced Ceramic Moisture
Sensor |
| Calibration Range |
Calibrated from -150 to +70°F dew
point |
| Power |
12-28 VDC loop powered (by
customer) |
| Output |
4-20 mA current loop powered,
configurable to include the entire range |
| Dew Point |
-150 to + 70°F (-100 to + 20°C)
or ppmv 0 - 3000 ppmv output or non-standard dew point range must be specified
at time of order |
| Accuracy |
±3.6°F dew point |
| Operating Temperature |
-40 to +140°F |
| Temperature Effects |
Temperature compensated across
operating temperature range |
| Operating Pressure |
6500 psig (max) |
| Flow Rate |
0-10 SCFH when mounted in an Easidew
Sample Block |
| Interchangeability |
Fully interchangeable transmitters |
| Sensor Protection |
<10 µ HDPE Guard (std.), 80
µ SS Sintered guard (optional) |
| Enclosure Rating |
NEMA 4X |
| Weight |
0.33 lbs |
| Fault Conditions |
Condition Output (Factory programmed)
Sensor fault 23 mA Under-range dew point 4 mA Over-range dew point 20 mA |
Easidew Transmitter Part
Numbers Standard Transmitter: EA2-TX Non Standard Range:
EA2-TX-w/xyz w = Zero value x = Full scale value y = Units (F =
°F dp, C = °C dp, & P = ppmv) z = Pressure for ppmv conversion
in BarG. Blank = 0 BarG
|
PANEL METER - An economical panel or
bench-mounted meter with digital display, analog outputs and dual alarm relays.
Display and output configurable as dew point (°F or °C) or ppmv
moisture content - Part number: EA2-OL-100 Easidew Sampler - A
self-contained sampling system, with filtration and flow control, for
measurement of pressure or atmospheric dew point - Part number: EA2-SAM
Sample Block - Stainless Steel sample block to contain Easidew Transmitter,
with 1/8 NPT ports - Part number: CSB Replacement HDPE Guard - Pack of 10 HDPE
Guards - Part number: EA2-HDPE-10 Sintered Guard - Stainless Steel
sintered guard, for protection of ceramic sensor (in place of standard HDPE
Guard) - Part number: 9980237 Easidew Communication Kit - for
connection to Easidew Transmitter for reconfiguration of range and output via
Michell Configuration Software (available free of charge from
www.michell.com) - Part number: EA2-CK |