| SENSOR |
| Measurement Range |
Calibrated from -150 to +70°F dew
point |
| Accuracy |
±1.8°F from +70 to -80°F
dew point; ±3.6°F from -80 to -150°F dew point |
| Resolution |
0.18 °F from -110 to +70°F dew
point; 1.8°F from -150 to -110°F dew point |
| Sensor Calibration |
Traceable to NIST |
| Process Connection |
5/8 UNF parallel thread |
| Enclosure |
Stainless steel |
| Ingress Protection |
NEMA 4X |
| Operating Temperature |
-40 to +140°F (compensated from -5
to +105°F) |
| Storage Temperature |
-40 to +165°F |
| Operating Temperature |
From vacuum to 5000 p.s.i.g. (max) |
| Flow Rate |
0-20 CFM at atmospheric pressure |
| Gas Velocity |
0-65 FPS (max) at atmospheric
pressure |
| Display |
Dual 6 digit LED, with 2 digit
engineering unit indicators |
| Units |
°F, °C dew point, %RH, ppmV,
ppmW, gm³, g/kg, °F, °C temp |
| Resolution |
0.01 for all units |
| ANALYZER |
| Measurement Units |
°F, °C dew point; ppmV with
user selectable range and resolution; Lb/MMscf range dependent on pressure
(natural gas); g/m³ (natural gas). Digital processing and linearization with
active or passive pressure compensation |
| Secondary Measurement Variable |
Pressure using an optional external
variable transducer over a range of 0-4000 p.s.i.g. Completely user-configurable
for any industry standard transducer with an 4-20 mA output. Automatic
compensation for ppmV, Lb/MMscf and g/m³ units. |
| Power Supply |
Universal 85 to 265 VAC, 50/60 Hz or 95
to 370 VDC |
| Ingress Protection |
NEMA 12 standard; NEMA 4X for front
panel only with optional cover |
| Operating Temperature |
-5 to +120°F |
| Alarm Relays |
Two user adjustable isolated 10A form
C rated at 240 VAC or 24 VDC: 8A (noninductive load) for set points
and fault detection standard |
| Outputs |
Analog: 4-20 mA as standard (max load
500 Ω) user configurable and scalable Digital: RS485: provides 2-way
communication - full data access to user and total availability of all set-up
and configuration |
| OPTIONS |
| Power Supply |
18 to 36 VAC; 9 to 60 VDC |
| Outputs |
Analog 0-20 mA optional (max load 500
Ω) or 0-10 V optional (min load 5 K Ω), user configurable and scalable |
| Relays |
1 or 2 additional 5 A relays (max 4
total) n/o type fully user configurable and adjustable over the full range,
full choice of units and sensor fault alarm functions |
| Cable |
Standard 6.5 foot (4000 foot max) |