| Performance |
| Measurement range (RH) | 0–100% RH |
| Measurement range (T) | -30 to +85°C / -22 to +185°F |
| Accuracy at 23°C / 73°F Humidity | <±2% RH (5–95% RH) |
| Accuracy at 23°C / 73°F Temperature | ±0.2°C (-10 to +50°C) ±0.36°F (+14 to +122°F) |
| Stability – RH Sensor | <±1% RH/year |
| Response time – RH Sensor | <10 sec typical (for 90% of the step change) |
| | |
| Electrical output/input |
| Output signal (RH) | 0–1 V |
| Output signal (T) | 3-wire 1/3 DIN Pt100 direct |
| Supply voltage | 5 VDC ±5% |
| Load resistance | R > 5K Ω Digital: CMOS compatible |
| Current consumption | 1.5 mA max |
| Operating conditions |
| Operating humidity | |
| Probe, Housing, Storage | 0–100% RH |
| Operating temperature | |
| Sensing element | -30 to +85°C / -22 to +185°F |
| Housing | -40 to +85°C / -40 to +185°F |
| Storage | -40 to +85°C / -40 to +185°F |
| | |
| | |
| | |
| Mechanical specification |
| Housing material | AISI 316 |
| Dimensions | L=53mm, ø22mm / L=2.08" x ø0.86" |
| Filter | AISI 316 Stainless steel mesh |
| | |
| Weight | 65g / 2.3oz |
| Electrical connections | Threaded nipple + nut |