Cermet II Hygrometer

A full specification on-line hygrometer for the measurement of dew point in air and process gases, with wide operating range and multiple display options.






Product Features

  • Wide measurement range, calibrated -100 to +20°Cdp
  • ±1.0°Cdp accuracy
  • Analogue and digital output
  • Pressure sensor input
  • Up to 4 alarm relays
  • User-selectable measurement units
  • Easy to read display
Cermet II

Technical Specification

Sensor
Measurement Range -100 to +20°Cdp
Accuracy (dew point) ±1°C from -60 to +20°Cdp
±2°C from -100 to -60°Cdp
Enclosure Stainless steel
Ingress Protection IP66 in accordance with standard BS EN 60529:1992
NEMA 4 in protection and accordance with standard NEMA 250-2003
Operating Temperature -40 to +60°C compensated over -20 to +40°C
Storage Temperature -40 to +109°C
Operating Pressure From vacuum to 40 MPa (400 barg/5801 psig) (max)
Flow Rate 1 to 5 Nl/min
Gas Velocity 0 to 10m/sec
Process Connection 5/8" UNF parallel thread
Sensor Calibration Traceable to UKAS and NIST
Analyzer
Measurement Units °C, °F dew point; ppmV with user selectable range and resolution; lb/MMscf range dependent on pressure (natural gas); g/m³ (natural gas)
Digital processing and linearization with active or passive pressure compensation
Resolution 0.1 °C from -80 to +20°Cdp
1°C from -100 to -80°Cdp
Secondary Measurement Variable Pressure using an optional external transducer over a range of 0-45 MPa (450 barg/6527 psig
Completely user-configurable for any industry standard transducer with an 4-20 mA output
Automatic compensation for ppmV, lbs/MMscf and g/m³ units
Alarm Relays Two user adjustable isolated 10A form 'C' rated at 240 V AC or 24 V DC
Outputs:
   Analog4-20 mA as standard (max load 500 Ω) user configurable and scalable
   Digital RS232
Power Supply Universal 85 to 265 V AC, 50/60 Hz or 95 to 370 V DC
Operating conditions
Operating Temperature
   Analyzer0 to +50°C
   Sensor -20 to +50°C (-5 to +122°F)
Ingress Protection
   AnalyzerIP54 (NEMA 12) standard (front panel only)
IP66 (NEMA4) with optional cover (front panel only)
   Sensor IP66 (NEMA4)
Options
Outputs:
   Analog0-20 mA optional (max load 500 Ω) 0-10 V optional (min load 5 K Ω) both user-configurable and scalable
   Digital RS485: provides 2-way communication - full data access to user and total instrument configuration
Alarm Relays 1 or 2 additional 5 A relays (max 4 total) n/o type fully user configurable and adjustable over the full range, full choice of units and sensor fault alarm functions
Power Supply 18 to 36 V AC; 9 to 60 V DC
Cable Standard 2m (1200m max)

Applications

Compressed Gas Breathing Air Natural Gas & Petrochemicals Power Generation Research & Development

Related Products

Easidew Online Easidew Online
A cost effective hygrometer with digital display, analogue and digital outputs and dual alarms...
DryCheck DryCheck
A simple and efficient, self-contained dew-point hygrometer, with filtration and flow control...
MDM300 & MDM300 I.S. (Intrinsically Safe) MDM300 & MDM300 I.S. (Intrinsically Safe)
High-speed portable dew-point hygrometer. Optional ATEX, IECEx, FM, CSA and GOST certification.
Optidew Optidew
The Optidew high performance optical dew-point transmitter is based on the proven, fundamental...
ES20 Compact Sampling System ES20 Compact Sampling System
The ES20 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a variety of industrial gas applications.