| Sensor Type |
XZR-500-ST + XCU-500-WM |
| Measurement Principle |
Zirconium Oxide Sensor with Metallic Sealed Reference and K Type T/C |
| Performance |
| Gas |
Wet, dirty and hot |
| Measurement Range |
0.01-25% Oxygen |
| Accuracy |
<2% relative with atmospheric
pressure compensation |
| Response Time |
< 15s for 90% of response step from
calibration gas inlet |
| Repeatability |
±0.1% |
| Fidelity |
1% per month |
| Linearity |
Better than ±1% |
| Sample Flow Rate |
Flue Gas at 0.5 m/s minimum rate |
| Maximum Sample Pressure |
Depending on application |
| Maximum Sample Temperature |
Up to 1300°C on request |
| Outputs |
| Output Signal |
One off 0/4 to 20 mA linear with
Galvanic Insulation Output; 2nd optional output |
| Output Load |
Over 1000 Ω |
| Self-diagnostics |
Included in Readout |
| Output Ranges |
Freely configurated between 0.01-25% |
| Alarms |
2 Alarms; User adjustable (10 W) 1
Fault Alarm |
| Display Resolution |
0.1% in standard; (0.01% on
request) |
| Power Supply |
115 or 220 VAC, 50/60 Hz |
| Power Consumption |
110 VA |
| Ambient Temperature Range |
0°C to 55°C |
| Sensor Temperature |
600 to 800°C, optimised at
700°C |
| Operating Humidity |
5-90% RH without condensation |
| Physical |
| Dimensions |
300 x 300 x 200 mm
(Control) 290 x 135 x 650 mm (Sensor) |
| Weight |
10 to 15kg depending on
application |
| Wetted Materials |
XZR-501- 304 L Stainless steel
(700°C) XZR-502- Inconel 600 (1000°C) XZR-503- HR160 (600°C
to 1000°C) XZR-504- C2000 (600°C) XZR-505- Halar coating
(120°C) XZR-506- Ceramic (1300°C) |
| Probe Dimensions |
Length 400mm, other on request |
| Installation |
Stack and wall mounting |
| Housing Ingress Protection |
Weatherproof |