| PERFORMANCE |
| Measurement Range (RH) |
0-100% RH |
| Measurement Range (T) |
-30 to +70°C |
| Accuracy RH @ 23°C |
<±2% RH (5-95% RH) |
| Accuracy T @ 23°C |
±0.4°C (-10 to +50°C) |
| Stability - RH Sensor |
<±1% RH/year |
| Response Time - RH Sensor |
<10 sec typical (for 90% of the step
change) |
| ELECTRICAL INPUT/OUTPUT |
| Output |
0-1, 0-5, 0-10 VDC 0–20mA, 4–20mA (3 wires) RS485 |
| Supply Voltage |
15 ≤ VAC ≤ 27
18 ≤ VDC ≤ 38 |
| Load Resistance |
Current output: R ≤ 500Ω |
| Current Consumption |
1.7 W |
| OPERATING CONDITIONS |
| Operating Temperature |
Probe: -30 to +85°C
Housing: -30 to +70°C
Storage: -40 to +70°C
|
| Operating Humidity |
Probe: 0–100% RH Housing: 0–100% RH Storage: 0–100% RH |
| MECHANICAL SPECIFICATIONS |
| Ingress Protection Sensor |
IP67 |
| Material |
Housing: Aluminium die casting
Probe: Delrin
|
| Electrical Connections |
Screw terminals |
| Dimensions |
Housing: 120 x 120 x 49.5 mm
Probe: L=100mm, ø19mm |
| Weight |
450g |