| PERFORMANCE |
| Measurement Range (dew point) |
-40 to +60°C, dew point
temperature |
| Accuracy (dew point) |
Typically ±2 °C (-20 to
+60°C) |
| Measurement Range (Absolute Humidity) |
-0 to 200g/m3 |
| Accuracy (Absolute Humidity) |
0.4-3g/m3 on value of absolute
humidity |
| Stability |
<1°C/year |
| Response Time |
<10 sec typical (90% of the step
change) |
| ELECTRICAL INPUT/OUTPUT |
| Output Signal |
0–1, 0–5, 0–10 V or 4–20mA |
| Supply Voltage |
8-30 VDC (14-30 VDC for 0–10 V
output) |
| Supply Voltage Influence |
±0.005% RH/V |
| Current Consumption |
9 mA + load current |
| OPERATING CONDITIONS |
| Operating Temperature |
Probe: -30 to +70°C Housing: -30 to +70°C Storage: -40 to +75°C |
| Operating Humidity |
Probe: 0–95% RH (non-condensing) Housing: 0–95% RH (non-condensing) Storage: 0–95% RH (non-condensing) |
| Operating Pressure |
20 Barg maximum |
| Temperature Coefficient |
±0.05% / °C |
| MECHANICAL SPECIFICATIONS |
| Ingress Protection |
IP65 |
| Housing Material |
Nickel-coated brass |
| Filter |
HDPE front filter |
| Mechanical Connections |
G1/2 (1/2” BSP) |
| Dimensions |
L=85mm, ø24mm (max) |
| Weight |
320g |
| Cable |
2m |