| PERFORMANCE |
| Measurement Range (RH) |
0-100% RH |
| Measurement Range (T) |
0 to +100°C, -20 to +80°C,
0 to +50°C, Pt100, Pt1000 |
| Accuracy RH @ 23°C |
RM52: <±2% RH (10 – 90% RH)
RM33: <±3% RH (30 – 80% RH) |
| Accuracy T @ 23°C |
RM52: ±0.2°C (-10 to +50°C)
RM33: ±0.3°C (+5 to +40°C) |
| Temperature Influence |
±0.05% RH/°C |
| Stability - RH Sensor |
<±1% RH/year |
| Response Time - RH Sensor |
<10 sec typical (for 90% of the step
change) |
| ELECTRICAL INPUT/OUTPUT |
| Output Signal |
4–20 mA (2-wires)
0–1 V, 0–5 V, 0–10 V |
| Supply Voltage |
14–35 VDC (for 0–5/10 VDC) 4.5–35 VDC (for 0–1 VDC) and
14–26 VAC |
| Supply Voltage Influence |
±0.01% RH/V typical |
| OPERATING CONDITIONS |
| Operating Temperature |
Electronics: 0 to +50°C Storage: -40 to +75°C
|
| Operating Humidity |
Probe: 10-90% RH Housing: 10-90% RH Storage: 10-90% RH |
PRT |
| Measurement Range |
Pt100/1000 -50 to +200°C
|
| Accuracy |
Pt100/1000 ±0.15% |
| MECHANICAL SPECIFICATIONS |
| Ingress Protection Sensor |
N/A |
| Housing Material |
White plastic
|
| Filter |
N/A
|
| Dimensions |
91 x 91 x 25.5 mm
|
| Weight |
85g |
| Electrical Connections |
Screw terminals
|