| PERFORMANCE |
| Measurement Range (RH) |
0-100% RH |
| Measurement Range (T) |
-40 to +95°C |
| Accuracy RH @ 23°C |
<±2% RH (5-95% RH) |
| Accuracy T @ 23°C |
±0.2°C (Pt100 Ω 1/3 DIN direct) |
| Stability - RH Sensor |
<±1% RH/year |
| Response Time |
<10 sec typical (for 90% of the step
change) |
| ELECTRICAL INPUT/OUTPUT |
| Output Signal |
I7000: 0–1V
I7400: 0.2–1V
Digital, variable frequency output |
| Output Signal |
3-wire 100 Ω 1/3 DIN direct Pt100 |
| Supply Voltage |
5 VDC ± 5% |
| Current Consumption |
≤ 1.5mA max |
| OPERATING CONDITIONS |
| Operating Temperature |
Probe: -30 to +85°C
Housing: -30 to +85°C
Storage: -40 to +85°C
|
| Operating Humidity |
Probe: 0–100% RH Housing: 0–100% RH Storage: 0–100% RH |
| MECHANICAL SPECIFICATIONS |
| Housing Material |
NORYL PPo UL 94 V0
|
| Electrical Connections |
RH: 3 wires
T: 3 wires |
| Dimensions |
L=33mm, ø14mm
|
| Weight |
3g |