XTP601 Series

 Zuurstof analyzer voor Eexd omgevingen
Michell Instruments introduceert de nieuwe XTP601. De XTP601 is gebaseerd op de beproefde, robuuste en corrosie bestendige thermo-paramagnetische analyser XTP600.

De XTP601 is een lineaire en stabiele zuurstof analyzer voor metingen in aardgas, biogas en inerte gassen.

De XTP601 is geplaatst in een explosie veilige behuizing en is ATEX Zone 1 gecertificeerd . De thermo-paramagnetische XTP601 zuurstof analyser is dan ook zeer geschikt voor gebruik in explosie gevaarlijk omgeving.



Product bijzonderheden

  • General purpose or ATEX, IECEx, CCSAUS, TC, TR & Ex hazardous area certified models
  • Ranges available: 0–0.5% up to 0–50% & 20, 80 or 90–100%
  • Touch-screen display allows calibration or adjustment without the need for a hot works permit
  • Intrinsic error (accuracy) is better than 1% full scale
  • Zero span stability better than 0.25% of span per month
  • Outputs include RS485 and two 4-20mA (following NAMUR NE 44 standard)
  • Low cost of ownership due to minimal maintenance and no consumable parts
XTP601

Technical Specification

Performance
Measurement TechnologyThermo-paramagnetic oxygen sensor
GasProcess and non-condensing sample with particles <5µm
Measurement RangeSelectable from 0–0.5% up to 0-50% and 20, 80 or 90–100%
Display Resolution0.01% for zero based ranges
0.1% for supressed zero ranges
Display TypeBacklit LCD
Accuracy Excluding Suppressed Zero Ranges±0.02% O2 or <±1% of span whichever is greater
Accuracy For Suppressed Zero Ranges (80/90 - 100%)±0.2% O2 or <±1% of span whichever is greater
Response Time (T90) with High Speed Response (HSR) Enabled< 15 seconds
Repeatability±0.2% of span or 0.01% O2 whichever is greater
Linearity±0.5% of span or 0.05% O2 whichever is greater
Zero Stability±0.25% of span per month
Span Stability±0.25% of span per month
Sample Flow Rate100 to 600 ml/min
Sample Flow EffectGP1 and GP3: 100 to 500 ml/min (0.2 to 1.06 scfh)
EX1, EX3 and GP2: 270 to 330 ml/min (0.2 to 1.06 scfh)
Sample Pressure0.75 to 2 BarA
Sample Temperature5 to +55°C max (+45°C for standard cell)
Sample Cell TemperatureStandard +50°C (Optional +55°C and +60°C for selected ranges and gases)
Background GasAnalyzer is calibrated in the background gas of the process. Standard gases are: N2, CO2, CH4, H2 & Biogas. Others available on request
Electrical Specifications
Analog Inputs2 off 4-20 mA inputs
One for an external sensor that can be displayed on the screen
One to act as an active compensation for the process conditions
Analog Outputs2 off 4-20 mA outputs (powered with 24V excitation voltage)
Output RangesPrimary range is set to the calibrated range of the instrument
The second is user configurable between 0-100%
Alarms2 off single pole changeover (SPCO) relays for O2 concentration (250 V, 5 A max)
DataloggingThe user can use the digital communications to log the output from the analyzer
The unit will store 40 alarm points and the min/max O2 concentrations with date and time stamp
Digital CommunicationsMODBUS RTU over RS485 Protocol
Power Supply24 V DC; 1.5 A max
Cable entriesAnalyzer is supplied with 3 x M20 cable entries. Cable glands, conduit entries and blanking plugs are available as accessories
Operating Conditions
Ambient Temperature5 to +55°C
Atmopheric pressure750mbar to 1250mbar
Mechanical Specifications
Warm Up Time<25 minutes
Stabilization Time5 minutes
Dimensions234 x 234 x 172mm (w x d x h)
Weight9.7kg
Wetted Materials316 & 430F stainless steel, boroscillicate glass, platinum, 3M 2216, plus O-ring
O-Ring MaterialsViton, Silicone or Ekraz
Gas ConnectionEX1, EX3 & GP2: 1/8” NPT (female)
GP1 and GP3: 1/4” NPT (female)
Ingress ProtectionIP66, NEMA 4X
Hazardous Area Classification
ATEXII 2GD Ex d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
IECExEx d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
CCSAUSClass I, Division 1, Groups B,C,D, T6
INMETROEx d IIB+H2 T6 Gb
Ex tb IIIC T85°C Db IP66
TC TR1 Ex d IIB+H2 T6 Gb
Temperature Ranges for ATEX and IECEx as per O-ring TypeSilicon: Ta = -40°C to +55°C
Viton®: Ta = -15°C to +55°C
Ekraz: Ta = -10°C to +55°C
The XTP601 process oxygen analyzer meets or exceeds all relevant clauses in BS EN 50104 : 2010
“Electrical apparatus for the detection and measurement of oxygen”.

Aanverwante artikelen

XGA301 XGA301
De XGA301 Industriële gas analyser van Michell Instruments biedt een handige platform voor het meten van zuurstof, dauwpunt en andere gassen zoals CO2, CO and CH4. De analyser is leverbaar in twee uitvoeringen met maximaal  3 sensoren gemonteerd.
XZR500 XZR500
Ontworpen om de optimale hoeveelheid lucht te bepalen bij verbrandingsprocessen. Door de MSRS technologie kan het zuurstofniveau in moeilijke omgevingen zoals boilers, verbrandingsovens en fornuizen, nauwkeurig worden bepaald bij hoge temperaturen en corrosieve omgevingen. De monstername gebeurt via een pitotbuis, en werkt in de meeste toepassingen uitstekend
XZR400TS XZR400 Series
Ontworpen voor de meting van rest zuurstof in zeer schone gassen. Wordt gebruikt om tijdens de fabrikage om de zuiverheid te controleren van gassen zoals Stikstof, Argon, Helium en Kooldioxide, de kwaliteit bij luchtseparatie plants, of kwaliteits analyse van aangekochte gassen. Zowel als wandmontage of voor gebruik in 19'' rekken.
Easidew PRO XP Easidew PRO XP
Explosieveilige dauwpunttransmitter, met een nauwkeurigheid van ±1°C dauwpunt. IECEx, CSA, FM and ATEX certification zorgen ervoor dat de Easidew PRO XP geschikt is voor een groot aantal toepassingen in gevaarlijke omgevingen. 3/4´´ UNF proces aansluiting
XTC601 binaire gas analyser XTC601
Een robuuste, lineaire en stabiele thermische geleidbaarheid analyser voor de meting van binaire gasmixen zoals lucht in Waterstof, Stikstof, Argon, Helium of Kooldioxide.