| Performance |
| Measurement Range (RH) |
0-100% RH |
| Measurement Range (T) |
-30 to +200°C |
Accuracy at 23°C Humidity |
<±2% RH (5–95% RH) |
Accuracy at 23°C Temperature |
±0.4°C |
| Stability - RH Sensor |
<±1% RH/year |
| Response Time - RH Sensor |
<10 sec typical (for 90% of the step change) |
| Electrical output/input |
| Output Signal |
0–1, 0–5, 0–10 V 0–20 mA, 4–20 mA, RS485 |
| Supply Voltage |
15 - 27 V AC / 18 - 38 V DC |
| Load Resistance |
Current output: R ≤ 500 Ω |
| Power Consumption |
1.7 W |
| Operating conditions |
Operating Temperature Probe Housing Storage |
-30 to +200°C -30 to +70°C -40 to +70°C |
| Mechanical specification |
| Ingress Protection Sensor |
IP67 |
Material Housing Probe |
Aluminium die casting Stainless steel |
Dimensions Housing Probe |
120 x 120 x 51mm L=134mm, ø12mm |
| Weight |
450g |
| Electrical Connections |
Screw terminals |