| Performance Specifications |
| RH measurement range | 0 to 100% RH |
| RH accuracy @ 23°C | ±1% RH (5 to 95% RH) |
| RH thermal coefficient | <0.03% RH/°C typical |
| RH resolution | 0.1% RH |
| RH measurement response time | <10 seconds |
| RH element and hybrid electronics | HygroSmart 3 technology |
| RH long term stability | ±1% RH per year |
| RH element and hybrid electronics | HygroSmart 3 technology |
| Temperature technology | PT100 1/3 DIN* |
| Temperature measurement range | –40 to +85°C |
| Temperature accuracy | ±0.2°C |
| Temperature resolution | Infinite |
| Electrical Specifications |
| Output signals | White housing: 0–1 V
Black housing: 0.2–1 V |
| Temperature output signal | Standard:
3-wire PT100 Optional: No output |
| Digital output signal | I2C interface |
| Supply voltage range | +5 V DC ±1 V |
| Power consumption | 300uA @ 5 V |
| Operating Specifications |
| Operating temperature | –40 to +85°C |
| Storage temperature | –40 to +85°C |
| Mechanical Specifications |
| Housing material | NORYL PPO UL94 V0 |
| Dimensions | L=33mm, ø14mm |
| Weight | 3g |
| Electrical connections | 7 pins |