GPR-1800/2800 AIS/IS

 Intrinsically Safe ATEX Analyzers
GPR-1800 ATEX Intrinsically Safe Oxygen Analyzer from AII

The GPR-1800 measures ppm levels of oxygen and offers optional Modbus RTU Communication and modular sampling system. It is available with alarm relays (GPR- 1800 AIS) or without (GPR-1800 IS).

GPR-2800 ATEX Intrinsically Safe Oxygen Analyzer from AII

The GPR-2800 measures percent oxygen and offers optional Modbus RTU Communication and modular sampling system. As with the GPR-1800, it is available with or without alarm relays.



Vorteile

  • 2 sensor options: ppm or percent
  • 12 to 28 V DC power or mains power (AIS only)
  • 2 x field selectable concentration alarms (AIS only)
  • Modbus communication (AIS only)
  • Optional sample system
  • Standard sample includes sample/span valve, moisture filter, flow meters
  • Optional fully automated sample system
GPR-1800/2800 AIS/IS

Specifiche Tecniche

Accuracy <2% of full scale range under constant conditions
Analysis Ranges GPR-1800
0-10 ppm, 0-100 ppm, 0-1000 ppm, 0.1%, 0-25% full scale ranges; auto-ranging or manually lock on a single range
GPR-2800
0-1%, 0-5%, 0-10%, 0-25% full scale ranges; auto-ranging or manually lock on a single range
ApprovalsCertified for use in hazardous areas
UL: United States: UL 1203, UL 913, UL 508
Canada: CAN/CSA C22.2 No. 30-M1986, CAN/CSA C22.2 No. 157-92, CAN/CSA C22.2 No. 14-10
ATEX: Directive 94/9/EC
Area Classification ATEX Certified: EX II 2 G Ex d [ib] ib IIB T4 Tamb -20 to +50°C
Alarms Two user configurable concentration alarm (AIS only)
Calibration 3 month interval using air or certified span gas with O2 value approx 80% of full scale range balance N2
CompensationTemperature as standard; barometric pressure AIS only
Connections1/8” compression tube fittings
ControlsWater resistant keypad
Menu driven range selection, calibration and system functions
DisplayGraphical LCD 70 x 35mm
Resolution 0.1 ppm
Displays real time ambient temperature and pressure
EnclosureNEMA Type 3R for rain in outdoor applications
FlowNot flow sensitive; recommended flow rate 0.4 to 0.9 Nl/min
Linerarity±1% of full scale
PressureInlet Regulate to 0.3 to 2 barg to deliver 0.4 to 0.9 Nl/min flow
Vent Atmospheric
Power12 to 28 V DC
110 to 220 V AC (AIS version only)
Response Time90% of final reading in 10 seconds
Sample SystemSample flow meter; options available
Sensitivity<0.5% of full scale range
Sensor ModelGPR-1800
GPR-12-333 or XLT-12-333 (for gases containing >0.5% CO2)
GPR-2800
GPR-11-32 or XLT-11-24 (for gases containing >0.5% CO2)
Sensor LifeGPR-12-333 or XLT-12-333
24 months in normal operating conditions O2 @ +25°C and 1 atmosphere
GPR-11-32
32 months in normal operating conditions @ +25°C and 1 atmosphere
XLT-11-24
24 months in normal operating conditions @ +25°C and 1 atmosphere
Signal Output4-20 mA
Modbus RTU communication (AIS only)
Operating Range-10 to +45°C (GPR sensor)
-20 to +45°C (XLT)
Warranty12 months analyzer
12 months sensor
Wetted PartsStainless steel

Applicazioni

Settore automoblistico   Aria per uso medicale e sicurezza  Aria Compressa  Produzione di Gas tecnici per industria  ettore Militare e Difesa  Industria alimentare nel settore delle bevande  Ricerca e sviluppo  Centrali di generazione energia elettrica 
Discariche  Industria chimica  Lavorazioni metalli e trattamenti termici  Settore farmaceutico e confezionamento 

Prodotti correlate

XZR400TS XZR400TS
L'analizzatore di Ossigeno mod. XZR400TS rileva tracce di ossigeno in gas e viene utilizzato per controllare la purezza di gas come azoto, argon, elio e anidride carbonica....
MDM25 XTP601 Series
Analizzatore di ossigeno robusto, stabile e lineare per misurazioni in gas come idrogeno, azoto o aria. Il sensore è alloggiato in un involucro molto resistente...